■TEMPERATURE MEASUREMENT RANGE:-20℃ - 400℃ (-4 ℉-752 ℉ )
■WORKING TEMPERATURE:0℃ - 50℃ (32℉-122℉ )
■WORKING HUMIDITY:< 90%RH (Non-Condensing )
■STORAGE TEMPERATURE:-20℃-60.0℃ (-4℉-140℉ )
■ACCURACY
■ AMBIENT TEMPERATURE:21℃-25℃,TEMPERATURE RANGE:-20℃≤t≤ 0℃,ACCURACY:±(2.0℃+0.1℃/℃)
■ AMBIENT TEMPERATURE:21℃-25℃,TEMPERATURE RANGE:0℃<t≤400℃,ACCURACY:±2.0℃ or ±2%
■ AMBIENT TEMPERATURE:69.8℉-77℉,TEMPERATURE RANGE:-4℉≤t≤32℉,ACCURACY:±(4.0℉+0.1℉/℉)
■ AMBIENT TEMPERATURE:69.8℉-77℉,TEMPERATURE RANGE:32℉<t≤752℉,ACCURACY:±4.0℉ or ±2%
■TEMPERATURE COEFFICIENT:±0.1℃ /℃ or ±0.1%/℃ (±0.1℉/℉ or ±0.1%/℉ )
■D:S:10:1
■EMISSIVITY:0.95(Not adjustable)
■SPECTRAL RESPONSE:7.5-13.5
■RESPONSE TIME:≤ 500ms(95% of reading)
■REPEATABILITY:1℃ or 1.0% (2℉ or 1.0% )
■DISPLAY RESOLUTION:0.1℃(0.1℉)
■UNITS:℃ or ℉ Convertible
■LASER SIGNAL:Single point
■LASER POWER:< 1mW
■LASER WAVELENGTH:630nm - 670nm
■LASER SAFETY LEVEL:CLASS 2 Complies with EN 60825-1: 2014 laser safety standards
■LASER SPOT:10m size of the laser spot : 10mm≤d≤ 15mm
■BACK LIGHT:Even orange light (not set) Backlight off in 15S
■AUTOMATIC POWER OFF:60s±1s(In HOLD mode)
■TYPE OF BATTERY:2*AAA(Zinc-manganese battery)
■OPERATING HOURS:20h(Continuous measurement mode, both laser and backlight are on)
■LOW BATTERY NDICATION:2.4VDC ±0.2VDC Display low battery sigh and flash 2.0VDC±0.2VDC power off
■WORKING CURRENT:≤25mA
■SHUTDOWN CURRENT:≤5μA
■EMC TEST:
■RE:30MHz - 1GHz CLASS A,Standard EN 61326-1: 2013,reference EN 55011: 2009 + A1: 2010
■RI:80MHz - 2.7GHz 3V/m CLASS A,Standard:EN 61326-1:2013,reference:EN61000-4-3:2006+A1:2008+A2:2010
■ESD: standard 4kv air 8kv CLASS B,standard EN 61326-1:2013,reference EN61000-4-2:2009
■DROP TEST:remains accurate after falling from a height of 1 meter
■NUMBER OF BUTTONS:2 buttons (Trigger and unit switch buttons)